Specifications — Pressure ratings at 70°F (PSIG)
| Size (NON)  | Corrugated Tubing ID (NOM)  | Casing OD (in.) 1B / 2B  | Max Working Pressure 1B / 2B  | Max Test Pressure 1B / 2B  | Nominal Burst 1B / 2B  | 
|---|---|---|---|---|---|
| ½ | 0.550 | 1.000 1.130  | 681 1,077  | 1,362 2,154  | 3,406 5,385  | 
| ¾ | 0.800 | 1.260 1.380  | 567 929  | 1,134 1,858  | 2,835 4,643  | 
| 1 | 1.025 | 1.650 1.780  | 554 907  | 1,108 1,814  | 2,769 4,533  | 
| 1¼ | 1.242 | 2.030 2.160  | 489 792  | 978 1,584  | 2,445 3,962  | 
| 1½ | 1.563 | – 2.530  | – 615  | – 1,230  | – 3,075  | 
| 2 | 1.992 | – 3.030  | – 493  | – 986  | – 2,463  | 
Chlorine Institute Pamphlet 6 Hose Assembly
- Hydrostatic tested at 2 times the MAWP
 - Commercial oven dried to ensure moisture is removed
 - Weld inspection with Helium Mass Spectrometer at a leak rate of 1 X 10ˉ9
 - Yearly samples tested at 5 times the MAWP and 2 times 15% deformation
 - Manufactured to ISO 10380 bending requirements
 - Procedures and Welder Qualifications in accordance with ANSI/ASME BPV‐IX AND ASME B31.3
 - Packaged, tagged, and all documentation per specification
 - Material verified using a calibrated handheld X‐ray Fluorescence Analyzer (PMI)
 
Download PDF