Specifications — Pressure ratings at 70°F (PSIG)
Size (NON) | Corrugated Tubing ID (NOM) | Casing OD (in.) 1B / 2B | Max Working Pressure 1B / 2B | Max Test Pressure 1B / 2B | Nominal Burst 1B / 2B |
---|---|---|---|---|---|
½ | 0.550 | 1.000 1.130 | 681 1,077 | 1,362 2,154 | 3,406 5,385 |
¾ | 0.800 | 1.260 1.380 | 567 929 | 1,134 1,858 | 2,835 4,643 |
1 | 1.025 | 1.650 1.780 | 554 907 | 1,108 1,814 | 2,769 4,533 |
1¼ | 1.242 | 2.030 2.160 | 489 792 | 978 1,584 | 2,445 3,962 |
1½ | 1.563 | – 2.530 | – 615 | – 1,230 | – 3,075 |
2 | 1.992 | – 3.030 | – 493 | – 986 | – 2,463 |
Chlorine Institute Pamphlet 6 Hose Assembly
- Hydrostatic tested at 2 times the MAWP
- Commercial oven dried to ensure moisture is removed
- Weld inspection with Helium Mass Spectrometer at a leak rate of 1 X 10ˉ9
- Yearly samples tested at 5 times the MAWP and 2 times 15% deformation
- Manufactured to ISO 10380 bending requirements
- Procedures and Welder Qualifications in accordance with ANSI/ASME BPV‐IX AND ASME B31.3
- Packaged, tagged, and all documentation per specification
- Material verified using a calibrated handheld X‐ray Fluorescence Analyzer (PMI)
Download PDF